Did you know ...
(C) VfNG / NEW
1. That suppress the SH-shku zero in the port # FF
Well nothing is impossible! Sam had so recently done, and
after the run up to a number of troubles. Why sprashivaetsya,
you can not? Da hell knows, but some controllers after zero to
the port # FF can only revive the whole pack of assorted
procedures, even with the Home interruption of all the other
teams do not always help. Not always possible, and a motor to
start. In addition, after the zero in the port # FF VG-scale
sort of believes that she zero road, and then the first call,
for example, # 3D13, if you really standing on the
n-dimensional track, and try that Anything with the track
considered, then plucked trying to put his head on the
controller 2 * n-ную road, which is very unpleasant.
As it is better to turn off the motor drive? I'm doing it
this way:
LD A, (# 5D16); Kopiya systemic Regis
; Spectrum
LD IX, # 1FF3; OUT (# FF), A: RET
PUSH IX
JP # 3D30
It seems to be so safe.
2. That before burning through # 3D13 by
specific path, if a motor is turned off
and head on it sticking out, then it is necessary to provide
positioning on this very track. The procedure itself is the
record plainly can not do, and some drives,
For example, EC-5311, can easily podporot drive. I have
personally seen it many times!
3. What if you ship or send via # 3D13 few small blocks in a
row, to expedite the appropriate after each call to # 3D13 to
do so:
LD A, (# 5D16)
OR # 2C
LD IX, # 1FF3
PUSH IX
JP # 3D30
This will prevent the possibility of a motor to slow down
between readings, and therefore not will need to spend time on
his peen. And everything will be cool.
Actually, I checked the installation # 5D16
Only after the procedure # 05, # 06 DOS. In
other times it sticks out something else
(When and what-not remember. It has long been on PZUshke
climbing).
That's all for now. If I'm somewhere was not
right, correct me on the pages of Echo!