Test v.4.30 & my Pentagon 128

ZXNet echo conference «real.speccy»

From Valeriy Kovalev To All 28 November 1999

Greetings, All!

Once Fri 26 Nov 1999 Felix Knajzev and Eduard Pilipenko
talked about Test v.4.30 & my Pentagon 512.


EP>> I mostly want to draw the attention of users
EP>> Pentagons.

EP>> After checking TR-DOS:
EP>> Data bus of this Spectrum in IM2 mode in
EP>> TR-DOS is clogged

I have the same thing.

FK> This is bad. Loaders with IM2 (music loaders) will fail
FK>. :( Ha

Only sometimes 7 REALITY in my multiloader is glitchy -
resets after loading.
All other multiloaders are ok.


What about other Pentagon owners with this glitch?

This was drawn by Valeriy Kovalev aka 500:17/1.8@ZXNet
Bye!

... message posted via ZXNet Gate.

From Musa Khaybullin To All 1 December 1999

EP>>> The data bus of this Spectrum in IM2 mode in TR-DOS is clogged

VK> I have the same thing.
It will be the same for everyone! It needs to be improved - it is necessary to add a /M1 signal to 15n D89(ID4)
by first cutting it off from the 14th leg.

FK>> This is bad. Loaders with IM2 (music loaders) will fail. :(

VK> My multiloader only sometimes has a glitch in 7 REALITY -
VK> resets after loading. All other multiloaders are ok.

VK> What about other Pentagon owners with this glitch?
How to fix the glitch, read above!

Yours sincerely, Musa Khaybullin.

From Dmitry Pavluhin To All 2 December 1999

I have this glitch, but it doesn’t show itself yet. In particular,
7th REALTy works fine.

Best regards, Dmitry.