Test v.4.30 & my Pentagon 128
ZXNet echo conference «real.speccy»
From Valeriy Kovalev → To All 28 November 1999
Greetings, All!
Once Fri 26 Nov 1999 Felix Knajzev and Eduard Pilipenko
talked about Test v.4.30 & my Pentagon 512.
EP>> I mostly want to draw the attention of users
EP>> Pentagons.
EP>> After checking TR-DOS:
EP>> Data bus of this Spectrum in IM2 mode in
EP>> TR-DOS is clogged
I have the same thing.
FK> This is bad. Loaders with IM2 (music loaders) will fail
FK>. :( Ha
Only sometimes 7 REALITY in my multiloader is glitchy -
resets after loading.
All other multiloaders are ok.
What about other Pentagon owners with this glitch?
This was drawn by Valeriy Kovalev aka 500:17/1.8@ZXNet
Bye!
... message posted via ZXNet Gate.
From Musa Khaybullin → To All 1 December 1999
EP>>> The data bus of this Spectrum in IM2 mode in TR-DOS is clogged
VK> I have the same thing.
It will be the same for everyone! It needs to be improved - it is necessary to add a /M1 signal to 15n D89(ID4)
by first cutting it off from the 14th leg.
FK>> This is bad. Loaders with IM2 (music loaders) will fail. :(
VK> My multiloader only sometimes has a glitch in 7 REALITY -
VK> resets after loading. All other multiloaders are ok.
VK> What about other Pentagon owners with this glitch?
How to fix the glitch, read above!
Yours sincerely, Musa Khaybullin.
From Dmitry Pavluhin → To All 2 December 1999
I have this glitch, but it doesn’t show itself yet. In particular,
7th REALTy works fine.
Best regards, Dmitry.