From Denis Dubodil To All 22 May 2006

Hello Orionsoft Ori> sparks in the nipple area or anywhere ? Ori> carefully peel back the skin from the nipple, there should be a hook there Ori> springs in the hole of the tube Ori> maybe there is no contact there I checked the pacifier, the contact is ok. Sparks anywhere in the area of uninsulated iron wires covering tube. More precisely in one place, you isolate it, it starts in others. It is also clear that sparks in the area of the gun inside the tube. If you remove the nipple, it doesn't spark, but the pipe still doesn't shine.

From Denis Dubodil To All 22 May 2006

Hello Orionsoft Ori> thick wire - this is probably the anode voltage?! Ori> there should be such a suction cup at the end Ori> it must be inserted into the connector in the tube itself and then there will be no sparks Ori> must. Ori> be careful there is high voltage! Ori> you need to wait 10-20 minutes after a complete shutdown, and only then Ori> ... The pacifier sticks out in the tube. It still sparks. The other end goes to the right (if look at the back) board.

From Orionsoft To All 22 May 2006

Hello Mike the thick wire is probably the anode voltage?! there should be a suction cup at the end it must be inserted into the connector in the tube itself and then there should be no sparks. Be careful there is high voltage! you need to wait 10-20 minutes after the complete shutdown, and only then...

From Orionsoft To All 22 May 2006

Hello, spleen spl> The pacifier sticks out in the tube. It still sparks. does it spark in the nipple area or anywhere? carefully peel back the skin from the nipple, there should be a hook that springs into tube hole maybe there is no contact there

From Orionsoft To All 22 May 2006

Hello, spleen spl> inside the tube. imho the anode is broken. Khan's pipe

From Vladimir Shevchenko To All 22 May 2006

Hello Orionsoft There is a thick wire running along the perimeter of the screen (around the entire kinescope). It's a loop demagnetization of the kinescope. Sometimes if she moves too close to high-voltage terminal of the kinescope (suction cup), a breakdown is possible in this place. Move as far as possible, additionally insulate with high-voltage material, if this is the case (electrical tape does not roll). In addition, there is a metal strip (bandage) along the perimeter of the kinescope, which is part of the kinescope (the “ears” are welded to it, for which the kinescope attached to the body). This strip must be grounded (that is, connected to weight of the apparatus). Check. I had a case where it broke between the suction cup and the bandage right through the glass kinescope, it was either dirty there or damp. Wiped it down so it was clean and dry, - everything stopped. In general, the area around the suction cup should be clean and dry, there is zone of pure glass, without graphite. A graphite coating is applied to most of the kinescope bulb. Don't wash it follows, it is necessary. This coating is also grounded using wires thrown directly across grounded wires (usually a multi-core braid from shielded wires). As I understand it, it sparks between the graphite and this braid? Then it looks like the graphite has been stressed. We need to find where it comes from. Either There is dirt around the suction cup, or maybe some other malfunction.If possible, it would be good to show it to specialists. It's a shame if Due to an incorrect diagnosis, a good kinescope will be rejected.

From ASDT To All 22 May 2006

Hello, spleen If it sparks in the pipe, the pipe is screwed.

From ASDT To All 22 May 2006

Hello, spleen There is a monitor repair conference, it seems... Breaks high...

From Denis Dubodil To All 22 May 2006

Hello ASDT ASD> If there is a spark in the pipe, the pipe is screwed. It sparkles both outside and inside. If you remove the suction cup, it doesn’t spark anywhere, but it doesn’t shows.

From Kirill Frolov To All 22 May 2006

Hello, spleen spl> It sparkles both outside and inside. If you remove the suction cup, it doesn’t spark anywhere, but spl> does not show. Find a book on TV repair. All standard schemes are there. A possible option is that you have, I don’t know what it’s called in human terms, but the anode voltage is clearly too high. And it’s really possible to sit behind such a monitor dangerous. If this is the World Trade Center - it's better to go straight to the trash - THE HUMPED GRAVE WILL FIX.

From Vladimir Shevchenko To All 22 May 2006

Hello ASDT ASD> If there is a spark in the pipe, the pipe is screwed. It may be so, but it cannot be said that it is always so. Possible on board Close the kinescope thread so that sparks appear in the neck of the kinescope. Try, for example, by jumping the terminals of the accelerating electrode and modulator to a perfectly working kinescope. It will sparkle again... But for this case it is, It doesn't seem to apply, since when you turn off the suction cup, the sparks disappear.

From Denis Dubodil To All 22 May 2006

Hello fk0 fk0> Find any book on TV repair. All standard schemes are there. fk0> fk0> A possible option is yours, I don’t know how it is humanly fk0> is called, fk0> but the anode voltage is clearly too high. And sit behind such a monitor fk0> real fk0> is dangerous. If this is the World Trade Center, it’s better to go straight to the trash heap - HUMPED GRAVE fk0> FIX. Electronics 32VTC 202. It’s a shame to throw it away.

From Denis Dubodil To All 23 May 2006

Hello, spleen spl> Electronics 32VTC 202. It’s a shame to throw it away. Threw it away.

From Vladimir Shevchenko To All 23 May 2006

Hello, spleen spl> Threw away. Monster :smile:

From Denis Dubodil To All 23 May 2006

Hello Orionsoft And they will charge you the same money as for a new SVGA

From Orionsoft To All 23 May 2006

Hello, Ball Bess Can I take it to a TV repair shop?!